Facade Systems
Concealed Fastener Rainscreen System
System Depth = 1 3/4” +  Universe Continuous Insulation System (1” to 3” thick as indicated on drawings)
Joint Width = 3/8”
 
System Components:
1.    EQUITONE Panel
2.    Universe Hanger Rail Extrusion – Black Color
3.    Extrusion Fastener
4.    Fixed Bracket (Shop Attached)
5.    Adjustable Bracket (Shop Attached)
6.    Tergo+ Secret Fix Undercut Anchor (Shop Attached)
7.    1/4” Thermal Isolator
8.    Continuous Insulation Vertical Wide-Faced Hat Extrusion Framing
9.    Wide-Face Hat Framing Fastener; attaches through mineral wool to substrate
10.    Roxul® ComfortBoard™ CIS 11# Density Mineral Wool Insulation
11.    Air & Moisture Barrier
12.    Sheathing
13.    16 Gauge Min. Steel Stud
 
Notes:
•    12mm thickness is required for [natura], [materia] and [pictura] material; 8mm thickness can be used for [tectiva] material.
•    Horizontally attached across framing.
•    Extrusions have splices for support between studs.
•    Insulation (10) must be Roxul® ComfortBoard™ CIS 11# Density mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly. The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.