Facade Systems
Concealed Fastener Rainscreen System
System Depth = 1 3/4" + Zee Girt
Joint Width = 3/8"
 
System Components:
1. EQUITONE Panel
2. Universe Hanger Rail Extrusion - Black Color
3. Universe Extrusion Fastener
4. Fixed Bracket (Shop Attached)
5. Adjustable Bracket (Shop Attached)
6. Tergo+ Secret Fix Undercut Anchor (Shop Attached)
7. 1/4" Thermal Isolator
8. Zee Girt
9. Mineral Wool Insulation
10. Air & Moisture Barrier
11. Sheathing
12. 16 Gauge Min. Steel Stud
 
Notes:
•    12mm thickness is required for [natura], [materia], and [pictura] material; 8mm thickness can be used for [tectiva] material.
•    Horizontally attached across framing.
•    Extrusions have splices for support between studs.
•    Insulation (9) must be mineral wool.  Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.  The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed.